Product Catalogue
Range of controlled liquid level | From 20 to 3000 (6000) m |
Range of measured annulus pressure | From 0 to 100 kgf/cm² |
Memory capacity | 12064 alphanumeric records/2605 charts |
Pressure resolution | 0,1 atm |
Battery operating ON-time, min | 14 hours** |
Battery charging time | 4 hours |
Operating temperature range | from - 40 ⁰C to +50 ⁰C |
Computer data transfer interface | USB / RS232*** |
Explosion proof protection / Ingress Protection Rating | 1 Ex ib IIB T3 X / IP54 |
Dimensions | 180х363х148 mm |
Weight | 3 kg |
The range of controlled liquid level | From 20 to 3000 (6000) m |
Range of measured annulus pressure in automatic mode | From 0 to 100 kgf/cm² |
Pressure range while controlling the level automatically | From 0 to 50 kgf/cm² |
Memory capacity | 12064 alphanumeric records/2605 charts |
Number of echometer shots without recharging the battery, min | 400 |
Pressure resolution | 0,1 atm |
Battery operating ON-time, min | 14 hours |
Battery charging time | 3,5 hours |
Operating temperature range | from - 40 ⁰C to +50 ⁰C |
Computer data transfer interface | USB / RS232*** |
Explosion proof protection / Ingress Protection Rating | 1 Ex ib IIB T3 X / IP54 |
Range of controlled liquid level | from 20 to 3000 (6000) m |
Range of measured annulus pressure in automatic mode | 0-100 kgf/cm² |
Pressure range while controlling the level automatically | 0-50 kgf/cm² |
Memory capacity | 12064 alphanumeric records/2605 charts |
Number of automatic echometer shots while GSM regime (under the temperature from – 40 ⁰C) | 200 |
The number automatic echometer shots with magnetic valve after total battery charge without GSM regime | 1000 |
Pressure resolution | 0,1 atm |
Battery charging time | 3,5 hours |
50 % battery charging time | 0,5 hour |
Operating temperature range | from -40 ˚С to +50 ˚С |
Computer data transfer interface | USB / RS232*** |
Explosion proof protection / Ingress Protection Rating | 1 Ex ib IIB T3 X / IP54 |
Range of controlled liquid level | From 20 to 3000 (6000) m |
Range of measured pressures | From 0 to 100 kgs/cm² |
Pressure resolution | 0.1 kgs/cm² |
Annular sound velocity range | 250-450 m/s |
Battery operating ON-time* | 35 hours |
Battery charging time | 8 hours |
Operating temperature range | from -40 ˚С to +50 ˚С |
Computer data transfer interface | USB |
Explosion proof protection / Ingress Protection Rating | 1 Ex ib IIB T3 X / IP54 |
Range of controlled liquid level | 20-3000 м (6000 м) |
Resolution | 1 m |
Range of measured annulus pressure | from 0 to 100 kgf/cm² |
Pressure resolution | 0,1 kgf/cm² |
Memory capacity | 3008 alphanumeric records/310 charts |
Number of echometer shots in automatic mode | 400 |
Battery charging time | 8 hours |
Operating temperature range | from -40 ˚С to +50 ˚С |
Computer data transfer interface | USB |
Explosion proof protection / Ingress Protection Rating | 1 Ex ib IIB T3 X / IP54 |
Our partners
Our partners
Datasheets
Datasheets
Our contacts
+7 (3822) 22-46-48